เครื่องมือจำลองการฆ่าเชื้อในผลิตภัณฑ์อาหารด้วยอุณหภูมิสูง HTST(High Temperature/Short time) /UHT ((Ultra-High Temperature) Pasteurization System Modular Miniature Scale Process System
28 มีนาคม 2566
ผู้ชม 253 ผู้ชม
SUMMARY.
Standard modules for direct heating (steam injection) or indirect heating (using tubular and/or plate heat exchangers), SSHE, aseptic processing, upstream or downstream homogenisation and additional chilling are available.
These, along with many other options, enable multiple modules to be included in the same system, giving high process adaptability by reconfiguration of flexible product hoses, using quick-release connections. The sterilisation options enable it to be linked to an Armfield sterile filling bench to produce sterile product, even when using long holding tubes and/or downstream homogenisation.
As with all Armfield systems, it comes with hygienic fittings throughout as standard, it is easy to clean and very flexible in use.
The touch-screen control panel makes it extremely user friendly to configure and monitor processing parameters. The operator is prompted at every stage whenever intervention is required.
BASE UNIT (FT174X)
The base unit comprises a stainless steel table for mounting the process equipment, a feed pump and vessel, the touchscreen control panel and all associated electrical controls housed in an IP65 cabinet.
On top of the table are four mounting positions for the selected heat exchangers. There is also space for a variable holding tube. Under the tabletop are storage positions for unused heat exchangers, plus space for the optional vacuum and extraction pumps used for direct heating. There is also space for the optional integrated homogeniser and CIP Pump.
The system is PLC controlled, with a high-resolution 8” full colour touchscreen panel. All operation functions are controlled from this panel, including configuration, mode of operation (sterilisation, process or Clean In Place).
Different sets of processing parameters can be edited, stored and quickly recalled using the system’s menu capability.
Similarly, the ancillary items such as the homogeniser and sterile filler are also controlled from this panel. The system can be quickly and easily interfaced to other free-standing Armfield process items, such as a mixing vessel, a chiller (FT63 or FT64) or a sterile filling system (FT83).
The base unit provides the services to the heat exchangers.
FOUR SETS OF SERVICES:
Preheat
A gentle preheat action is achieved by using steam at sub-atmospheric pressure (and hence low temperature). In this way, steam temperatures at or significantly below 100°C can be produced, and low differentials between steam temperature and product temperature are achieved. Stable temperatures of 60°C or less are feasible. Control of the steam pressure/temperature is achieved by a manual steam-control valve. Automatic PID control is an available option.
Cooling
Cooling water is applied to the cooling section of the product heat exchanger via a rotameter in order to measure flow rate.
Main heat
Steam is applied to the service side of the heating section of the product heat exchanger using an electro-pneumatic steam-control valve. The product temperature is measured at the end of the heat exchanger (or holding tube) and this value is used by a PID control algorithm, implemented in the PLC, to control the steam-regulating valve ensuring the user defined set point is maintained. The same steam output and control valve is used to provide the steam injection for the optional Direct Steam Injection module.
Chilling
(Optional), using an external recirculating chiller such as the Armfield FT63, FT64 or other chilled water supply.
Feed pump system
A progressing cavity feed pump is used as this gives consistent volumetric flow rate for a wide range of liquid viscosities.
It consists of a stainless steel rotor within a food-grade rubber stator. All metal parts of the pump, which come into contact with product are made from 316l stainless steel. A mechanical seal isolates the product from the drive system.
This pump provides a very wide range of flow capability, from as low as 10 L/hr to as much as 150 L/hr (used for CIP). The pump is fitted with a feed tank and level sensor, a pressure-relief valve and temperature and pressure sensors.
FEED PUMP SYSTEM
A progressing cavity feed pump is used as this gives consistent volumetric flow rate for a wide range of liquid viscosities.
It consists of a stainless steel rotor within a food-grade rubber stator. All metal parts of the pump, which come into contact with product are made from 316l stainless steel. A mechanical seal isolates the product from the drive system.
This pump provides a very wide range of flow capability, from as low as 10 L/hr to as much as 150 L/hr (used for CIP). The pump is fitted with a feed tank and level sensor, a pressure-relief valve and temperature and pressure sensors.
SOFTWARE
The armBUS software enables the operator to select the appropriate stage of the process and a mimic diagram with measured variables is displayed. The speed of the pump can be varied to meet the required flow rate.
Results are saved in a log, which can be viewed and manipulated with the armBUS results viewer. Results can be printed or exported in a spreadsheet format, which can be opened in a wide range of packages for further analysis.
Option (To be defined at time of order).
FLOW METER OPTION (FT174-40)
The standard unit displays an estimated flow rate calculated from the feed pump speed. This is accurate enough for many applications, but where more accuracy is required, a flowmeter is available for measuring the product flow rate.
SUCTION FEED ASSEMBLY (FT174-41)
The FT174-41 blanks off the hopper feed port and allows product to be drawn from an upstream tank or vessel. When no more product is available, the float switch detects this and sends a 10 second warning to the operator before engaging a safety cut-out to protect the system.
PNEUMATIC BACK PRESSURE VALVE ACCESSORY (FT174-42)
The FT174-42 is a pneumatic pinch valve, which provides much better performance than the standard sprung-back pressure valve when used with products containing particulates. Pressure control in the system can be more finely regulated.
ADDITIONAL COOLING STAGE (FT174-43)
Adds the location points and plumbing for a fourth heat exchanger (second-stage cooling). Necessary accessory when using FT174-26 DUAL.
STERILISATION OPTION (INDIRECT HEATING) (FT174-45)
Sterilization is achieved by applying steam onto the outside of the cooling tubes instead of cold water. This sterilizes the cooling tubes and gives the power to sterilize a downstream homogenizer. The FT174-45 option provides the switching valves necessary to perform this. The FT174-45 is only needed when using indirect heat exchangers for the main cooling (i.e. not using the [D.S.I. and] vacuum cooling vessel). However, FT174-45 components need not be removed when a vacuum module is fitted.
CONTROLLABLE PREHEAT OPTION (FT174-46)
This option is required when it is necessary to achieve an accurate preheat temperature (e.g. when it is important to homogenize at a particular temperature) or when using the preheat facility by itself for pasteurizing at lower temperatures. It is also beneficial when using direct steam injection.
It replaces the standard manual preheat control valve with an automatically controlled electro-pneumatic valve. A PID loop is used to control the temperature to the operator's desired set point by actuation of the valve. The option also includes an electronic pressure sensor to measure the steam pressure. This pressure and its equivalent temperature (determined in the PLC) are displayed on the control panel.
DIRECT INJECTION OPTION (FT174-48)
The same steam valve used to provide the main heating on an indirect heat exchanger can be used to provide the steam control for a direct injection heat exchanger. The heat exchangers themselves therefore become interchangeable.
The option comprises:
- Steam-conditioning unit, built into the service unit frame –including a culinary grade steam filter to clean any impurities from the steam prior to injection
- Steam-injection port
When using direct steam injection, conventional tubular (or plate) heat exchangers are used in position one for preheat and four for final cooling.
VACUUM EVAPORATOR MODULE OPTION (FT174-49)
This module is used in conjunction with a direct system injection to evaporate away the injected steam and prevent dilution of the product.
It comprises:
- A module assembly located in position three, including:
– Vacuum vessel with sight glass.
– Back pressure valve on inlet.
– Tubular HE (two tubes) for cooling priorto the extraction pump.
– Pressure (vacuum) sensor and temperature sensor.
– Mounting position for the steam injector, FT174-48. - Vacuum pump assembly mounted below the table with isolator valve and bleed valve
- Extraction pump to pump out the contents of the vessel against the vacuum
STERILE VACUUM MODULE FT174-55 (USED INSTEAD OF FT174-49).
This module is an alternative to the vacuum module, which is modified to make sterilization possible.
The module adds a hygienic divert valve prior to the vacuum chamber, a cooling heat exchanger, a sterile breather and a second valve and steam trap at the filler (FT83). Steam is used to sterilize the system, and injected through the direct injection port.
The divert valve enables the product to be diverted away from the vessel until it is fully up to temperature keeping the vessel sterile during processing.
CONTROLLED COOLING (FT174-51)
This option, used in conjunction with secondary cooling, allows the user to define an outlet product temperature. Flow rate of the secondary coolant is automatically adjusted to attain the defined temperature.
CIP SYSTEM FOR FT174 (FT174-52)
The FT174X has an efficient CIP facility built-in as standard. Should the unit be used for especially fouling products where very high cleaning velocities are required then this option may be specified. It includes a dedicated centrifugal pump which augments the cleaning provided by the feed pump.
PRESSURISED HOT WATER HEATING (FT174-58/FT174-59)
Secondary hot water heating circuits between the steam & product streams. This gives clear control over the temperature of the process temperatures less 100ºc. When processing sensitive viscous products at lower temperatures, the accessory gives more stability in the temperature control.
SCRAPED SURFACE HEAT EXCHANGER OPTIONS (FT174-75)
Scraped surface heat exchangers can be fitted at any position (preheat, main heat, cooling) for use with viscous products. Product flow rates would be typically 10-20 l/hr.
HOMOGENISER ASSEMBLY (FT174-91)
Twin-piston two-stage variable flow rate homogenizer with pulsation damping devices, bleed valve to control input pressure, plus temperature, product line pressure and homogenization pressure sensors all integrated within the FT174X frame, enabling upstream or downstream processing.
The homogenizer is controlled from the FT174X touchscreen.
The pump speed can be automatically controlled to match the product flow rate.
Homogenization pressure: 400 bar max or 600 bar max
Maximum flow rate: 55 l/hr or 20 l/hr
Option (May be added at any time).
STATIC MIXERS (FT174-21)
Static mixers are available to promote turbulence in the tubes and improve heat transfer. One set provides mixers for two tubes.
TUBULAR HEAT EXCHANGER (FT174-25)
A single bank of four tubes, with a temperature sensor. The product flows through the centre while the service fluid (heating or cooling fluid) flows through the outer tube.
The FT174-25 is normally used for lower flow rates, (typically 10-20 l/hr).
Can be used for :
- Preheat
- Cooling
- Main heat (indirect)
- Chilling
i.e. more than one FT174-25 can be used at the same time.
TUBULAR HEAT EXCHANGER (FT174-26)
A single bank of eight tubes, with temperature sensor.
The product flows through the centre while the service fluid (heating or cooling fluid) flows through the outer tube.
The FT174-26 can achieve higher flow rates than the FT174-25, (typically up to 60 l/hr).
Can be used for :
- Preheat
- Cooling
- Main heat (indirect)
- Chilling
i.e. more than one FT174-26 can be used at the same time, and FT174-26s can be mixed and matched with FT174-25s.
DUAL COOLING (FT174-26-DUAL)
When the direct steam injection option has been specified then the position normally taken for the primary cooling heat exchanger is unavailable. If low product outlet temperatures are still required, then a dual cool heat exchanger can be specified for the final position. This is a 16-tube heat exchanger, eight tubes for primary cooling and a further eight tubes for secondary cooling.
PLATE HEAT EXCHANGER (FT174-36)
Single stage plate heat exchanger comprising 18 plates.
Can be used for :
- Preheat
- Cooling
- Main heat (indirect)
- Chilling
i.e. more than one FT174-36 can be used at the same time, and FT174-36s can be mixed and matched with tubular heat exchangers if required.
SUCTION FEED ASSEMBLY WITH AUTOMATIC CHANGEOVER (FT174-53)
This option adds an automatic water feed to the suction feed assembly (FT174-41) so that should a low feed level situation occur, the unit can switch to a pressurized water feed automatically. This means the operation of the HTST system is not interrupted and sterility is not broken.
VARIABLE HOLDING TUBE (FT174-65)
Provides nominal holding times of 15, 30, 45, 60, 75, 90, 105, and 120s for a flow rate of 20 l/hr.
Note: FT174X display shows the actual hold time based on the measured or estimated flow rate used during processing.
OTHER HOLDING TUBES
Other holding tubes can be provided to suit your holding time and flow rate requirements. Please contact us with your specific requirements.
APPLICATION.
- Baby foods.
- Beer.
- Beverages.
- Condiments.
- Confectionery.
- Milk.
- Cream.
- Ice-cream.
- Yogurts.
- Desserts and puddings.
- Fruit and vegetable purées.
- Fruit juices and cordials.
- Sauces and soups.
- Gravies.
- Gelatine products.
- Pet food.
- Health and nutritional products.
- Culture media.
- Proteins.
- Pharmaceuticals.