Applied Scientific Instruments Co., Ltd.

บริษัท แอพพลายด์ ไซแอนทิฟิค อินสตรูเม้นท์ส จํากัด

ศูนย์รวมเครื่องมือทดสอบ เครื่องมือวิทยาศาสตร์ เครื่องมือวิเคราะห์ทุกชนิด

 

ติดต่อสอบถาม

ผ่าน LINE ID

@asithailand

 

Wetted Wall Gas Absorption Column

หมวดหมู่สินค้า: CE SERIES - CHEMICAL ENGINEERING
รหัส : CES
Wetted wall columns may be used to determine gas/liquid mass transfer coefficients, essential when calculating the design of absorption towers.

29 พฤษภาคม 2566

ผู้ชม 631 ผู้ชม

DESCRIPTION

Wetted wall columns may be used to determine gas/liquid mass transfer coefficients, essential when calculating the design of absorption towers. Such coefficients form the basis of correlations used to develop packed towers.

CES examines the absorption of oxygen from air into deoxygenated water (prepared by nitrogen sparging). This is an example of liquid film controlled absorption.

The liquid film mass transfer coefficient can be determined at various mass flow rates of water.

The system components are mounted within a floor standing painted steel framework.

The wetted wall column is a glass column with water inlet and outlet sections and is gimbal mounted to ensure that it can be set accurately in a vertical orientation.

The deoxygenating column is of similar overall size to the wetted wall column, standing vertically adjacent to it. Beside the column is a control console housing flow meters, pump controls and oxygen analyser. Situated between the columns are two special housings containing the oxygen analysis probes which monitor the oxygen content in the water entering and leaving the absorption column. The apparatus uses water as the working medium, contained in a storage tank at the rear of the unit. Pumps delivering water to the deoxygenator and the absorption column are located at the base of the unit.

In operation, water is sparged with nitrogen in the deoxygenator before entering the top of the wetted wall column. Air is pumped by the integral diaphragm-type air pump into the base of the column. The air passes up the column, giving up the oxygen to the water. Dissolved oxygen at inlet and outlet can be measured in rapid succession. The water drains into the storage tank to be recycled to the deoxygenator.

 

TECHNICAL SPECIFICATIONS

  • WETTED WALL COLUMN

    Height: 900mm
    Internal diameter: 32mm
    Material: Glass

  • DEOXYGENATING COLUMN

    Height: 1570mm
    Internal diameter: 26mm
    Material: Clear acrylic
    Range: 600-5000 ml/min

  • WATER FLOW METER

    Range: 20-280 ml/min

  • DEOXYGENATOR

    Feed pump: 20 l/min @ 2m head
    Absorption column feed pump: 10 l/min @ 1m head
    Air feed pump: 24 l/min @ 1 kg/cm2
    Sump tank capacity: Approx 40l

     

  • XYGEN METER

    Saturation

    Range: 0-199.9%
    Accuracy: ± 0.5%
    Resolution: 0.1%
    Temperature compensation: 0-50°C automatic

  • CONCENTRATION

    Range: 0-19.9ppm
    Accuracy: ± 0.2ppm
    Resolution: 0.1ppm
    Temperature compensation: 0-50°C automatic

  • TEMPERATURE

    Range: -100°C to +200°C
    Accuracy: ± 0.3°C
    Resolution: 0.1°C

 

EXPERIMENTAL CONTENT

  • Calculation of liquid film mass transfer coefficients
  • Variation of coefficient with mass flow rate
  • Variation of oxygen flow rate to determine power law relationship
  • To determine the power-law relationship between the liquid film mass transfer coefficient

 

ขอใบเสนอราคา

ดาวน์โหลดโบว์ชัวร์

 

 

Engine by shopup.com