Applied Scientific Instruments Co., Ltd.

บริษัท แอพพลายด์ ไซแอนทิฟิค อินสตรูเม้นท์ส จํากัด

ศูนย์รวมเครื่องมือทดสอบ เครื่องมือวิทยาศาสตร์ เครื่องมือวิเคราะห์ทุกชนิด

 

ติดต่อสอบถาม

ผ่าน LINE ID

@asithailand

 

BeScan Lab

หมวดหมู่สินค้า: Bettersize
รหัส :
The BeScan Lab is a versatile, sensitive, and reliable stability analyzer utilizing Static Multiple Light Scattering (SMLS) technology. It is widely employed in formulation development and product quality control. This analyzer can handle a broad range of sample concentrations (up to 95% v/v) and various types such as emulsions, suspensions, and foams, with temperature scanning capabilities up to 80°C. BeScan Lab offers both qualitative analysis and quantitative detection of destabilization, aiding in achieving long-term product stability and optimal shelf life.

18 มิถุนายน 2567

ผู้ชม 211 ผู้ชม

BeScan Lab

The BeScan Lab is a versatile, sensitive, and reliable stability analyzer utilizing Static Multiple Light Scattering (SMLS) technology. It is widely employed in formulation development and product quality control. This analyzer can handle a broad range of sample concentrations (up to 95% v/v) and various types such as emulsions, suspensions, and foams, with temperature scanning capabilities up to 80°C. BeScan Lab offers both qualitative analysis and quantitative detection of destabilization, aiding in achieving long-term product stability and optimal shelf life.

Features and Benefits

  • Real stability analysis for dispersions with volume fraction up to 95%.
  • Particle size ranges from 10 nm to 1 mm.
  • Non-destructive testing: non-contact, non-diluting, and non-shearing.
  • Data acquisition with a resolution of 20 μm enables quicker observation of sample stability than with the naked eye.
  • Precise temperature control up to 80°C to accelerate unstable phenomena.
  • "One-to-many" system enables simultaneous testing of different samples with one software.
  • Identification of various unstable phenomena: creaming, sedimentation, flocculation, coalescence, and breaking.
  • Quantification of destabilizations and study of mechanisms.

Measurement Principle 

Static Multiple Light Scattering (SMLS) is employed to characterize the stability of dispersions. Within BeScan Lab, a setup comprising two detectors and an LED light source ascends along the sample cell to conduct sample scanning. In the case of concentrated samples, the backward detector is employed to detect backscattered signals, while for diluted samples, the forward detector is utilized to detect transmitted signals.

how-BeScan-Lab-woks

The sample will undergo scanning every 20 μm vertically to capture changes in transmitted and backscattered signals, indicating destabilization. Following each scan, an instability index (IUS) can be computed. Short-term or Long-term stability can then be assessed based on the trend of IUS.

stability-calculation-formula

figure-BeScan-Lab data results

Mean particle size measurement can be implemented by analyzing transmission, backscattering, or particle migration rate. Investigation of particle size facilitates the research on unstable phenomena.

 

Applications 

Petrochemicals, Pharmaceuticals, Agrochemicals, Food & Beverages, Chemicals, Paints, Inks & Coatings, Ceramics, Battery & Energy

BeScan Lab applications

Simple and Intuitive Software 

With our powerful software, the BeScan Lab Stability Analyzer enables rapid and highly sensitive testing, facilitating the characterization of unstable phenomena.

Qualitative analysis:

BeScan-Lab-Qualitative-analysis

 

Quantitative analysis:

♦ Instability index (IUS)

The stability can be quantitatively analyzed using IUS, which is determined by integrating the variations in the sample.

BeScan-Lab-Quantitative-analysis

♦ Radar chart

Global and local instability indices for each scanning are illustrated in form of a radar chart, intuitively providing a way to investigate local stability (top, middle, and bottom).

BeScan-Lab stability analyzer-Radar-chart

♦ Temperature trend testing

Temperature trend testing enables stability analysis over different temperatures. Temperature is a critical factor that affects system stability. It is of vital importance to find out the change point.

BeScan-Lab-stability analyzer Temperature-trend-testing

♦ Peak thickness analysis

Scatter plot of peak thickness demonstrates how fast the particles settle or float upward. Besides, the mean particle size based on gravitational liquid sedimentation can be obtained.

BeScan-Lab-Peak-thickness-analysis figure

 Specification

Parameters Values
Measurement principle SMLS (Static Multiple Light Scattering)
Detection angle 0° transmission and 135° backscattering
Light source 850 nm LED
Scan step 20 μm
Maximum volume fraction 95%
Measurement range of particle size 0.01 - 1000 μm
Temperature range RT+5 ℃ - 80 ℃ (±0.5 ℃ )
Sample volume 4 - 25 mL
Measurement mode Regular/Fixed point/Temp. trend
Dimension 460(L) x 260(W) x 280(H) mm
Weight 13.5 kg
Power AC100 - 240 V, 50 - 60 Hz, 3.8 A
ISO compliance

ISO/TR 18811:2018, ISO/TR 13097:2013

ISO/TR 21357:2022, ISO/TS 22107:2021

 * Sample and sample preparation dependent

 