INOPS Series Horizontal Steam Sterilizer
21 กุมภาพันธ์ 2567
ผู้ชม 80 ผู้ชม
INOPS Series Horizontal Steam Sterilizer
Horizontal Steam Sterilizer is strictly designed and manufactured in accord with GMP technical Standard. It has passed ISO9001 quality management qualification standard and ISO13485Certificate of Quality Management System for Medical Devices.The relevant data can be saved and printed automatically. This autoclave is suitable for hospital, scientific research institute and other units to sterilize asepsis clothes, tools, ulture medium and so on.
FEATURES
Description:
Horizontal Steam Sterilizer is strictly designed and manufactured in accord with GMP technical Standard. It has passed ISO9001 quality management qualification standard and ISO13485Certificate of Quality Management System for Medical Devices.The relevant data can be saved and printed automatically.
This autoclave is suitable for hospital, scientific research institute and other units to sterilize asepsis clothes, tools, ulture medium and so on.
Features:
-
Horizontal square inner chamber + jacket structure,safety, heat preservation, and drying function;
-
Disc type embedded gear + Electric lock door structure,safety and reliable;
-
The door seal is pneumatic, single or double door(double door interlock)
-
Equipped with standard equipment verification interface
-
Pipeline system for the optimal design, SUS304 pipeline, clamp structure, quick assembly
-
Control system: HMI man-machine interface,touch screen+PLC
-
F0 value and temperature time double guarantee sterilization effect, with perfect sterilization records;
-
With program selection, parameter setting, equipment operation, report processing and traceability Functions;
-
Three levels of authority management
-
Multiple safety protection(over-temperature, over-pressure protect)
-
Sterilization process: fabric, equipment, liquid, BD,pressure testing, custom defined multiple procedures
SPECIFICATIONS
Technical parameter:
Model | INOPS-150D (S)(M) |
INOPS-200D (S)(M) |
INOPS-300D (S)(M) |
INOPS-400D (S)(M) |
INOPS-600D (S)(M) |
INOPS-800D (S)(M) |
INOPS-1000D (S)(M) |
INOPS-1200D (S)(M) |
INOPS-1500D (S)(M) |
Volume | 150L | 200L | 250L | 360L | 600L | 800L | 1000L | 1200L | 1500L |
Power(KW) | 2+18 | 2+18 | 2+24 | 2+24 | 3+36 | 3.5+45 | 3.5 | 4.5 | 4.5 |
Voltage | Three-phase five-wireAC 380V、50HZ | ||||||||
Design pressure | -0.1~0.3Mpa | ||||||||
Design temperature | 144℃ | ||||||||
Rated working pressure | 0.245Mpa | ||||||||
Working temperature | 105-138℃ | ||||||||
Vacuum | -0.086Mpa | ||||||||
Temperature Equilibrium | <+2.0℃ | ||||||||
Water Pressure | 0.1-0.2Mpa | ||||||||
Compressed air pressure | 0.4~0.7Mpa | ||||||||
Steam Pressure | 0.3-0.7Mpa | ||||||||
Cycle time per batch | About 40-70 minutes | ||||||||
Overall Dimensions (L*W*H)mm |
950*1120*1760 | 1175*1120*1760 | 1030*1300*1900 | 1250*1300*1900 | 1440*1310*1900 | 1700*1310*1900 | 1500*1440*1950 | 1700*1440*1950 | 2100*1440*1950 |
Chamber Size (L*W*H)mm |
450*480*700 | 450*480*925 | 600*600*780 | 600*600*1000 | 610*910*1190 | 610*910*1450 | 680*1180*1250 | 680*1180*1450 | 680*1180*1850 |
Steam Consumption (KG) | ≤14 | ≤16 | ≤18 | ≤25 | ≤30 | ≤35 | ≤42 | ≤50 | ≤60 |
Water Consumption (KG) | ≤190 | ≤190 | ≤200 | ≤200 | ≤210 | ≤220 | ≤200 | ≤200 | ≤200 |
Net Weigh(KG) Single/Double door |
700/750 | 830/880 | 980/1050 | 1080/1150 | 1150/1250 | 1200/1300 | 1380/1500 | 1530/1650 | 1680/1800 |