Applied Scientific Instruments Co., Ltd.

บริษัท แอพพลายด์ ไซแอนทิฟิค อินสตรูเม้นท์ส จํากัด

ศูนย์รวมเครื่องมือทดสอบ เครื่องมือวิทยาศาสตร์ เครื่องมือวิเคราะห์ทุกชนิด

 

ติดต่อสอบถาม

ผ่าน LINE ID

@asithailand

 

PETRODIST 300 CC fully automatic

หมวดหมู่สินค้า: Pilodist
รหัส : PETRODIST 300 CC

31 กรกฎาคม 2565

ผู้ชม 152 ผู้ชม

Summary

Processor controlled Crude oil distillation system according to ASTM D-1160. System for determination of boiling ranges of crude oil products under vacuum in fully automatic operation.

Special advantages of the new PETRODIST® 300 CC are:

  • Computer as parameter input and display unit as well as calculation of distillation and final data and print out of the distillation curve via
    PILODIST IP65 IP65 user interface with 15,6” touch screen and new laser printer
  • Menu control guarantees uncomplicated operation
  • Flexible parameter selection makes using of the system for continuous problem definitions possible
  • Distillation can be performed under different pressure steps
  •  Greese free operation to avoid contamination with the product
  • 2 independent safety circuits for flask heatingMass balance availability
  • Calculation of charge according to receiver temperature and charge density
  • Detailed distillation data by self-calibrated accurate volume measuring system
  • Distillation results available in the following formats: pdf, xls, csv, txt
  • Distillation reports and curves can ever be re-called
  • Perfected safety system
  • Minimum installation effort as the system is delivered ready for operation

The distillation is automatic, from the initial boiling point to the pre-selected end boiling point or detected break-off. The criteria for break-off are:

  • the pre-selected final AET (atmospheric equivalent temperature) is reached
  • the maximum bath temperature is reached
  • the maximum flask temperature is reached
  • the pre-selected distillate volume is reached
  • the flask insert cracks
  • the distillate pressure drops
  • product lack in the flask

The distillation volume is measured automatically in a tempered receiver. The yield is calculated in percentage to the charge quantity. Distillation report, final data and distillation curve are printed out.

 

Specification

Technical Points Description
 Available flask sizes  500 mL
 Flask charge  200 mL
 Operating temperature  up to 400° C (750° F)
 Final cut temperature  up to 650° C AET (1202° F)
 Max ambient temperature  25° C
 Operating pressure  vacuum down to 1 Torr
 Mains supply  208 – 250 V, 50 Hz (60 Hz upon request)
 Power consumption  3500 W (without options)
 Dimensions (w x h x d)  approx 0.65 x 0.64 x 0.96 m

 

ขอใบเสนอราคา

ดาวน์โหลดโบว์ชัวร์

 

 

Engine by shopup.com